SUB-STATION_& POWER FACILITIES

SUB-STATION_& POWER FACILITIESA grid substation is where transmission voltages come to be stepped up/stepped down in three phase transformers. Electrical substations are mandatory for all the processes of the power grid. Electrical equipment represents essential scope of devices used to generate electrical power from the substations. Such equipment is installed in the substations for communication, relaying or for supervisory control. It protects the power system component against abnormal conditions such as faults. Substations also allow engineers to diagnose problems with the system and perform diagnostics on the system itself (and the substation equipment).

Instrument transformersRecommended tests:

  • Capacitance and dissipation factor (C-tan δ)
  • Turns ratio
  • Winding resistance (only on current transformers)
  • Excitation Current (only on current transformers)
  • Knee of point (only on current transformers)
  • Polarity check
  • Insulation resistance
  • Burden
  • BDV Test

Recommended tests:

  • Contact resistance
  • Opening and Closing Time
  • Insulation resistance

DISCONNECTORSRecommended tests:

  • Contact resistance

ROTATING MACHINESRecommended tests:

  • Capacitance and dissipation factor (C-tan δ)
  • Winding resistance
  • Winding inductance
  • Insulation resistance

STATIONARY BATTERIESRecommended activities:

  • Depth discharge
  • Measurement of the voltage during discharge cells
  • Measurement of the electrolyte density of the cells (only on acid stationary batteries)

CAPACITOR BANKSRecommended tests:

  • Measurement of the capacitance of the batteries
  • Insulation resistance

Recommended tests:

  • Very Low Frequency (VLF) Testing
  • Insulation resistance
  • Locating a defect
 
 
 
 
 

POWER CABLES-2

RELAY PROTECTION EQUIPMENTPrimary and secondary testing of the protection relays

  • Protection relays testing with primary injection single phase up to 800A
  • Three phase systems up to 35A

SURGE ARRESTERSRecommended tests:

  • Measurement of discharge current
  • Insulation resistance

Thermal imaging can locate the hot spots of the weak contacts, asymmetrical load in the electrical equipment installed in the power facilities and sub-stations

Recommended tests:

  • Earth resistance
  • Specific earth resistance (soil resistivity)
  • Step and contact voltage
  • Continuity of the grounding system
  • Prevectron lightning protectionGROUNDING AND LIGHTNING SYSTEMS-2

LOW VOLTAGE INSTALLATIONSRecommended tests:

  • Prospective Short Circuit Current (Z line)
  • Prospective Earth Fault Current (Z loop)
  • Insulation Resistance
  • Phase sequence check
  • Continuity of grounding

Equipment